+86 4008836695 (24 hours service)


















Product Specifications
| Model | KL-6300-S1 | KL-6300-S2 | KL-6300-S3 | KL-6300-S4 | KL-6300-S5 | KL-6300-P1 | KL-6300-P2 | KL-6300-P3 | KL-6300-M | KL-6300-MS | |
| Wavelength (nm) | 1310/1550 | PON 1310/1550/1625 (built-in filter) | 850/1300 | 850/1300+1310/1550 | |||||||
| Dynamic range (dB) | 32/30 | 35/33 | 40/38 | 42/40 | 45/43 | 32/30/28 | 38/36/34 | 42/40/40 | 20/22 | 20/22 32/30 | |
| Number of optical port | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 2 | |
| Event dead zone★① (m) | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 1 | 1 | 0.8 | 1.5 | SM≤1;MM≤1.5 | |
| Attenuation dead zone★② (m) | 3 | 3 | 2.5 | 2.5 | 2.5 | 3 | 3 | 2.5 | 5 | SM≤3.5;MM≤5 | |
| Multi-fiber Measurement | √ | √ | √ | ||||||||
| Multi-pulse Measurement | √ | × | √ | ||||||||
| Splitters Measurement | Max 1:32 | Max 1:64 | Max 1:128 | Max 1:32 | Max 1:64 | Max 1:128 | × | Max 1:32 | |||
| Applicable fiber | SM (ITU-T G.652) | ||||||||||
| Distance range (km) | 0.1, 0.3, 0.5, 1.3, 2.5, 5, 10, 20, 40, 80, 120, 160, 260, 320 | ||||||||||
| Pulse width (ns) | 3, 5, 10, 30, 50, 100, 200, 300, 500, 1000, 2500, 5000, 10000, 20000 | ||||||||||
| Number of sampling points | ≥250000 | ||||||||||
| Sampling resolution | Min 0.04m | ||||||||||
| Distance measurement accuracy | ±(0.75 m + Measurement distance × 2 × 10⁻⁵ + Sampling resolution) | ||||||||||
| Loss measurement accuracy | ±0.03 dB/dB | ||||||||||
| Return loss measurement accuracy | ±2 dB | ||||||||||
| Optical Power Meter Module (Built-in) √ | |||||||||||
| OPM | Wavelength | 800 ~ 1650nm | |||||||||
| Measure range | -70 ~ +6dBm | ||||||||||
| Measure accuracy | < (±0.2dB or ±5%) | ||||||||||
| Display resolution | 0.01dB | ||||||||||
| Optical input port | 2.5mm Universal ferrule for FC, SC, ST/UPC | ||||||||||
| Stabilized Light Source Module (Built-in) √ | |||||||||||
| SLS | Wavelength (nm) | 1310/1550 | 1310/1550/1625 | 850/1300 | 850/1300+1310/1550 | ||||||
| Output power | ≥-10dBm | ||||||||||
| Modulation mode | CW, 270 Hz, 1 kHz, 2 kHz | ||||||||||
| Laser class | Class 1M or Class 1 | ||||||||||
| Optical input port | OTDR port | ||||||||||
| Visual Fault Locator Module (Built-in) √ | |||||||||||
| VFL | Wavelength (nm) | 650±10nm | |||||||||
| Output power | 10mW | ||||||||||
| Modulation mode | CW, CHOP (2 Hz) | ||||||||||
| Laser class | Class 3R | ||||||||||
| Optical input port | 2.5 mm Universal ferrule type for FC, SC, ST | ||||||||||
| Fiber Inspection Probe (Built-in) Optional | |||||||||||
| FIP | Pass / Fail | √ | |||||||||
| Magnification | 400X | ||||||||||
| Resolution(um) | ≥1.0 | ||||||||||
| Electrical interface | USB2.0 | ||||||||||
| Optical Connector | FC/UPC, SC/UPC, ST/UPC | ||||||||||
| CMOS size | 1/3 inch | ||||||||||
| General Specifications | |
| Link Map | √ |
| Pass/Fail judgment | √ |
| Distance unit | m, km, mile, kf |
| PC Analysis Software | √ |
| Languages | English, Español, Chinese, Português, Français, Русский, ภาษาไทย, 한국어 |
| Optical connector | FC/UPC (SC/UPC/APC、LC/UPC/APC、FC/APC Optional) |
| Display | 7-inch touch screen (Resolution: 1024 × 600) |
| Port | Charge port × 2, 12V - 2.5A & Type C |
| Operating temperature | -10 ~ 50°C (0 ~ 40°C when AC adapter is being used. 0 to 35°C when battery is charged) |
| Storage temperature | -20 to 60°C |
| Altitude | 4000 m |
| Humidity | 0 to 90% RH (20 to 90% with AC adapter, non-condensing) |
| Power requirements | 100 - 240V AC, 50/60Hz (AC adapter) |
| Battery | 7.4V, 10500mAh, ≥77Wh |
| LED Light illumination | >15000mcd |
| Operating time★③ | 12 hours |
| Data storage | Internal storage: ≥10000 traces, External storage: USB memory |
| Dimensions | 232 mm (W) × 161 mm (H) × 70 mm (D) |
| Weight | 1.6 kg (including internal battery and protectors, excluding OTDR unit and options) |
Notes:
★①. Minimum pulse width, return loss: ≥55 dB (≥40 dB for 850/1300 nm), group refractive index: 1.5, the unsaturated peak level <1.5dB.
★②. Minimum pulse width, group refractive index: 1.5, the backscatter level is >0.5dB of the normal level. For SMF, at 1310nm, return loss: ≥55dB. For MMF, at 850nm, return loss: ≥40dB.
★③. New Battery All specifications valid at 23°C ± 2°C (73.4°F ± 3.6°F) unless otherwise specified.